Description
- Matte Collection
- Developed with Dentists
- Soothes & Comforts The Baby
- 94% Nipple Acceptance¹
- Skin Soft™ Silicone
- BPA° BPS Free
- International Children Medical Research Society
- Using Our Sterilizer Box Saves Up To 77% of Energy & CO2
Shield
- Curved for maximum comfort
- Gentle on skin with big air holes and unique inside surface
Button
- Easy to hold
- Easily attaches to a clip
Skinsoft™ Silicone
- Easily accepted by babies
- For a familiar feeling
MAM Nipple
- Orthodontic
The MAM Principle
Parents are demanding. At MAM, we are too. That's why, for over 45 years, we have worked with medical and research experts to develop products that are unique in function and design. MAM products support the individual development of every child and make everyday life easier for babies.
Nipple with SkinSoft™ Silicone surface feels familiar to babies.
MAM Pacifiers are the result of our close collaboration with pediatricians, dentists and orthodontists. The natural-feeling nipple is comfortable for babies and reassuring for parents. The special nipple and shield design ensure a perfect fit and skin-friendly shape. Proven effectiveness: market research confirms that 94% of babies accept the MAM SkinSoft™ Silicone nipple. (Market research 2010-2019, tested with 1,463 babies).
UPC
845296064448Ingredients
All MAM products are made from materials free of BPA and BPS.
Suggested Use
Remove tamper-proof closure and any stickers from the box.
Wash pacifiers and box with mild soapy water and then rinse with clear water before use. This is to ensure hygiene.
When using the self-sterilizing method, please ensure the pacifier, box and microwave (including the waveguide-cover and turntable) are completely clean and free from dirt, food residue, fat or oil splashes. If not, this could lead to the product or box melting and the microwave sparking or the waveguide cover burning!
First, hold box and fill to the mark with 25 ml/ 0.9 fl. oz. of water (Fig. A). Next, place pacifier(s) in the box with the nipple facing down (Fig. B).
Close box and heat in the microwave at 750-1000 watts.
Set the microwave timer according to the number of boxes being simultaneously sterilized.
Number of Double Boxes | 1 | 2 | 3 |
Recommended sterilizing time in minutes | 3 | 7 | 9 |
Follow the user manual of your microwave. Don't put the sterilizer box at the center of the turntable. Don't leave your microwave unattended during sterilizing process! Stop the microwaving- process immediately if the water has evaporated.
Allow to cool for at least 5 minutes.
Open microwave. caution! The box, water and pacifiers may still be very hot after the 5 minute cooling period!
After microwave sterilizing, pacifiers kept in the closed box will remain disinfected for up to 48 hours.
For immediate use open box and drain remaining water. Leave pacifiers to dry in slightly open box.
Check the temperature of the pacifiers before use!
Improper water level, power level or time setting can damage the microwave, pacifiers and box and result in poor disinfection!
For use only with MAM Pacifiers!
Keep sterilizer box away from children.
- Before first use boil in water for 5 minutes.
- Allow to stand for a further 5 minutes before giving it to the baby.
- During cleaning a small amount of water may enter the nipple. This can be expelled by squeezing and shaking the nipple. This is to ensure hygiene.
- Clean before each use. Sterilizing methods: steam sterilizing (electric or microwavel, immersing in a liquid sterilizing solution, all according to manufacturer's instructions, or boiling in water for at least 5 minutes.
- Do not use aggressive cleaning agents.
- Never dip the nipple in sweet substances or medication. This can cause tooth decay.
- To ensure safety and hygiene replace the pacifier every 1-2 months.
- Do not worry if the pacifier becomes lodged in the mouth.
- It cannot be swallowed and is designed to cope with such an event. Remove as gently as possible.
- Keep the pacifier in daylight-not direct sunlight - during the day so that the button glows in the dark. The glow button will not charge under LED light.
- MAM recommends giving up pacifier usage at 3 years of age.
Warnings
Do not tie pacifier around child´s neck as it presents a stangulation danger.
Safety instructions inside. Please read before use.
For your child´s safety warning!
Inspect carefully before each use. Pull pacifier in all directions. Throw away at the first signs of damage or weakness.
Only use dedicated pacifier holders tested to EN 12586. Never attach other ribbons or cords to a pacifier, your child may be strangled by them.
Do not leave a pacifier in direct sunlight or near a source of heat or leave in sterilizing solution for longer than recommended, as this may weaken the nipple.
Sterilizer box instructions for use:
Remove any stickers from the box. Wash pacifiers and box with mild soapy water and then rinse with clear water before use. This is to ensure hygiene. When using the self-sterilizing method, please ensure the pacifier, box and microwave (including the waveguide-cover and turntable) are completely clean and free from dirt, food residue, fat or oil splashes. If not, this could lead to the product or box melting and the microwave sparking or the wave-guide cover burning First, hold box andfill to the mark with 25 ml/0.9 fl oz of water (Fig. A). Next, place pacifier(s) in the box with the nipple facing down (Fig. B). Close box and heat in the microwave at 750-1000 watts. Set the microwave timer according to the number of boxes beni ng simultaneously sterilized (Fig. C). Follow the user manual of your microwave. Don't put the sterilizer box at the center of the turntable. Don't leave your microwave unattended during sterilizing process. Stop the microwaving-process immediately if whole water is vaporised. Allow to cool for at least 5 minutes. Open microwave.
The box, water and pacifiers may still be very hot after the 5 minute cooling period. After microwave sterilizing, pacifiers kept in the closed box will remain disinfected for up to 48 hours. For immediate use open box and drain remaining water. Leave pacifiers to dry in slightly open box. Check the temperature of the pacifiers before use. Improper water level, power level or time setting can damage the microwave, pacifiers and box and result in poor disinfection. For use only with MAM Pacifiers. Keep sterilizer box away from children.